ADW310 IoT Single phase Wireless Smart Energy Meter

Short Description:

● Wireless Comms.: 4G, WiFi (MQTT, MODBUS-TCP)
● Wired Comms.: RS485 (MODBUS-RTU)
● Rated Voltage: 220~264Vac L-N
● Rated Current: 20(100)A AC (via paired CT) 
● Measurement: 1-phase Active&Reactive Energy, Active&Reactive Power, Current, Voltage, Frequncy, Power Factor, Apparent Power
 I/O Function: 1-way DI & 1-way DO
● Temperature: 2-way Cable Temperature Measurement
● Pulse Output: Active Pulse Output


Product Detail

Parameter

Download

Instructions

Product Features

1672819101707

Online&Remote Energy Monitoring

● Paired with Acrel IoT Energy Monitoring System 

● PC Access via IoT EMS WEB

● Mobile Phone Access via IoT EMS APP

● 4G Wireless Communication (Global)

● WiFi Wiress Communication (2.4GHz)

● Support MQTT, MODBUS-TCP protocol

● Support standard RS485 interface (MODBUS-RTU)

1676271965813

Wiring Diagram

1676272241655

Outline Dimension

1676272268937

Dimension of paired CT for ADW310

1676272632784

Application in IoT Solution

WiFi Based Solution

qqq

4G Based Solution

zzz

  • Previous:
  • Next:

  • 1. Function Overview

    Function Description
    Measurement
    (Standard)
    Single-phase AC Active&Reactive Energy (both forward and backward), Active Power, Reactive Power, Current, Voltage, Frequency, Power Factor, Apparant Power, Frequency
    Measurement
    (Optional)
    Temperature Measurement:2-channel (Live line,Neutral line) Cable Temperature Monitoring;  Thermistor:NTC;  Range: -40~+99℃;  Accuracy:±2℃
    Communication
    (Standard)

    RS485 Port with Modbus-RTU protocol -  1 start bit,8 data bit,1 stop bit,no parity;  Baud Rate 1200~38400 bps etc.

    Infrared Communication – Constant Baud Rate 1200 bps

    Communication
    (Optional)
     

    4G LTE – Normal Communicaiton Module Support: LTE-FDD: B1/B3/B5/B8;  LTE-TDD:B34/B38/B39/B40/B41

    4G LTE – Global Communication Module Support: LTE-FDD:B1/B3/B5/B7/B8/B20/B28;  LTE-TDD:B38/B40/B41

    WiFi – Support 2.4GHz or 5GHz

    Protocol (For wireless Communication): MQTT and MODBUS-TCP

    Display
    (Standard)

    LCD Display and LED Indicator

    HMI
    (Standard)

    Keypads Programming: Setting of CT/PT Ratio, Communication, Phase Wiring and etc

    Software
    (Standard)

    Adjustment Software: Setting of Data Upload Interval, WiFi configuration (Account&Password), Server Address, Port and etc 

    Alarm Function
    (Standard)
    Undervoltage, Overvoltage, Undercurrent, Overcurrent, Underload, Overload, Communication Disconnection and etc
    I/O Function
    (Optional)

    1-channel DI (Digital Input)

    1-channel DO (Digital Output)


    2. Main Parameters

    Parameter Description&Value
    Voltage
    Input
    Rated Voltage 220~264Vac L-N
    Reference Frequency 45~65Hz
    Power Consumption <0.5VA (each Phase)
    Current
    Input
    Rated Current 20(100)A AC
    Starting Current 1% Ib (Class 0.5); 4% Ib(Class 1)
    Power Consumption <1VA (each Phase)
    Phase
    Wiring
    1P2W 1-phase 2-wire
    Measurement
    Performance
    Standard GB/T17215.322-2008,GB/T17215.321-2008
    kWh Accuracy Class 1
    Pulse
    Width of Pulse 80±20ms
    Pulse Constant 1600imp/kWh;

    3. Environment

    Condition Description&Value
    Temperature

    Operating Temperature: -25℃~+55℃;  Storage Temperature: -40°C ~+70°C

    Humidity

    ≤95%RH,no condensation,without corrosive gas

    Altitude

    ≤ 2000m