Acrel EMS 2.0 can monitor and analyse the power, grid, loads, energy storage and charging. Realize the data interaction among each systems. Improve energy efficiency, lower cost, achieve carbon peaking and carbon neutrality.
![]() |
APM520 Three phase panel meter
Full electric parameter measurement (I, U, kW, kvar, kWh, kvarh, Hz, cos); four-quadrant electric energy, split-phase electric energy, apparent electric energy; real-time demand and maximum demand; electric parameter extreme value and last month Monthly extreme value; voltage and current unbalance; voltage and current phase angle; total harmonic and 2nd-63rd subharmonic; voltage crest factor, telephone waveform factor, current K coefficient, vector diagram, voltage and current waveform; last 128 pcs of DIDO Records; the latest 128 pcs of alarm records; default switch communication 4DI2DO2EP1C;
|
![]() |
APM830 Three phase panel meter
Three-phase (l, U, kW, kvar, kWh, kvarh, Hz,PF), zero sequence current In, four-quadrant electric energy; real-time and maximum demand; extreme values of this month and last month, current and voltage imbalance,Load current histogram display; 66 alarm types and 16 external events (SOE) each with16 event records, support SD card expansion record; 2-63 time harmonics; 2Dl+2D0.RS485/ modbus; LCD display |
![]() |
ADW300 Wireless energy meter
1.Three phase voltage, current, frequency 2.Three phase power, total power (active, reactive, apparent) 3.Positive and negative active/reactive electrical energy, four quadrant reactive electrical energy, multi tariff 4.Voltage and current phase angle, voltage and current imbalance 5.Voltage, current total harmonic and 2-31st harmonic 6. Record of extreme values of voltage, current and power in current month and last month 7. Maximum current, power demand and real-time current, power demand ADW300, connected via current transformer, supports common current transformer connection ADW300W, equipped with 3 split core CTs (mA output), which can be used as 5A (secondary transformer) and 100A input |
![]() |
APView 500 power quality analyzer
Real-time voltage and current waveform; Voltage deviation,Frequency deviation, 2nd-63rd Harmonics voltage/current, 0.5th-62.5th Interharmonics voltage/current, Voltage flicker,Voltage fluctuation,Rapid voltage change; Voltage interruption,Voltage swell,Voltage dip; Transient current,Transient voltage; Event recorder;Waveform recorder; PQDIF saved;WebServer RS485 (2 ports);Ethernet(4 ports); GPS timing(IRIG-B);USB (1 port) Accessories: IEC61850 |
![]() |
ANet-2E8S1 smart gateway
1.Support Modbus-RTU,Modbus-TCP,DLT645,IEC103,IEC104,CJT188 protocols 2.Support HTTP(S)XML and JSON forwarding format. 3.2 channels 10/100M Ethernet port. 4.Max.8 channels RS485, Support Max.256 devices 5.Support SD card interface(max.32GB) 6.Multiple alarm setting for each device. |
![]() |
ARD3M Series Smart Motor Protector
Measure three-phase current, overload,blocking, locking.overload, phase off,imbalance, PTC protection, etc., Standard 10D1/6DO programmable, 2 channels Modbus-RTU |
![]() |
AM5SE series protection relay
Protection relay with function Directional overcurrent, overcurrent IDMT, earth fault, earth fault IDMT, overload, trip and close circuit supervision, loss of voltage, PT supervision, three phase auto-reclose, under frequency, over frequency, Post-Accelerated overcurrent, overvoltage, residual overvoltage,directional power, FC block, RS485 (2 ports), modbus serial, IEC 60870-5-103, IEC 60870-5-101, tripping context records, SOE, electric parameter (U, I, P, Q, PF, F, Ep, Eq, Es), remote control, GPS. |