EMS3.0 Energy management system

Short Description:

https://ems.acrelcloud.cn/ECEMS

Demo account : visitor

Password: 123456


Product Detail

Overview

Acrel EMS 3.0 can dispatch and manage power, grid, loads, energy storage and charging. To lowerthe cost, improve the renewable energy usage efficiency, benefit from peak valley arbitrage, demand management and VPP transaction.

1

Architecture

Clean power generation 》

Reliable power distribution 》

Efficient power usage 》

Optimal control》

2

Related products

3 APM520 Three phase panel meter Full electric parameter measurement (I, U, kW, kvar, kWh, kvarh, Hz, cos);

four-quadrant electric energy, split-phase electric energy, apparent electric energy;

real-time demand and maximum demand;

electric parameter extreme value and last month Monthly extreme value;

voltage and current unbalance;

voltage and current phase angle;

total harmonic and 2nd-63rd subharmonic;

voltage crest factor, telephone waveform factor, current K coefficient, vector diagram, voltage and current waveform;

last 128 pcs of DIDO Records;

the latest 128 pcs of alarm records;

default switch communication 4DI2DO2EP1C;

4 APView 500 power quality analyzerReal-time voltage and current waveform;

Voltage deviation,Frequency deviation,

2nd-63rd Harmonics voltage/current,

0.5th-62.5th Interharmonics voltage/current,

Voltage flicker,Voltage fluctuation,Rapid voltage change;

Voltage interruption,Voltage swell,Voltage dip;

Transient current,Transient voltage;

Event recorder;Waveform recorder;

PQDIF saved;WebServer

RS485 (2 ports);Ethernet(4 ports);

GPS timing(IRIG-B);USB (1 port)

Accessories: IEC61850 

5 AM5SE-IS Anti-islanding protection relayOvercurrent,directional overcurrent (with voltage dependant, 3 stages),

CT supervision,2 stages earth fault ,overcurrent IDMT,earth fault IDMT,

overload,trip and close circuit supervision, loss of voltage (trip), loss of voltage (alarm) ,

PT disconnection alarm,three phase auto-reclose,under

frequency,over frequency, post-accelerated

overcurrent,overvoltage protection,residual overvoltage protection

,directional power,FC block,synchro-check, rate of change of frequency,

auto-close with voltage recovery,over haul-lockout,auto-close with power recovery,loss of power.

6 ANet-2E8S1 smart gateway1.Support Modbus-RTU,Modbus-TCP,DLT645,IEC103,IEC104,CJT188 protocols

2.Support HTTP(S)XML and JSON forwarding format.

3.2 channels 10/100M Ethernet port.

4.Max.8 channels RS485, Support Max.256 devices

5.Support SD card interface(max.32GB)

6.Multiple alarm setting for each device.


  • Previous:
  • Next: