AMC16Z-ZD DC Incoming Line Monitoring Module

Short Description:

● Rated Voltage: 48VDC,240VDC,336VDC

● Rated Current: 5V (Hall sensor,powered by AMC16Z-ZD ±12V)

 Communication: RS485 (MODBUS-RTU)

 Accuracy: Voltage/current Class 0.5,power/electric energy Class 1

 Switch output: 2 channels (3A 250VAC/3A 30VDC)

 Switch input: 6 channels

 Installation: DIN35mm

● Standard&Certificate: CE; IEC; LVD;ROHS


Product Detail

parameter

General

AMC16Z series multi-loop acquisition module is independently designed to meet the needs of the increasingly high precision power distribution management requirements of the data center. It suitable for various all-round intelligent monitoring of terminal distribution equipment.

Function

● Monitor the full-power parameters of the A+B double-channel DC feed circuit

● Measurement Voltage,current,power,electric energy,ambient temperature and humidity

● 2nd~63rd&Total Harmonic

● ±12V output (only power supply to the feed circuit module supporting Hall sensor).

● 1-way temperature and humidity detection

Network Schemes

1

Product Selection

2

Wiring Diagram

1

Cabinet Diagram

2

Dimensions & Installation

3
4

AMC16Z-FAK24 Terminals

5

AMC16Z-FAK48 Terminals

6

Applications

7

Site Installation Photos

822

  • Previous:
  • Next:

  • DC incoming line

    Instrument model

    AMC16Z-ZD

    Measured parameters

    Voltage,current,power,electric energy,ambient temperature and humidity

    Bus voltage

    Rated

    48VDC,240VDC,336VDC

    Measured range

    ±20%

    Overload

    Instantaneous voltage 2 times per second

    Current incoming line

    circuit

    Rated

    5V (Hall sensor,powered by AMC16Z-ZD ±12V)

    Overload

    Duration 1.2 times,instantaneous 10 times/second

    Temperature and humidity

    Temperature range

    -40℃-+99℃

    Humidity range

    20%-90%

    Measurement

    precision

    Incoming line

    Voltage/current Class 0.5,power/electric energy Class 1

    Temperature

    ±1℃

    Humidity

    ±5%

    Auxiliary power

    Signal take electricity(≤15W)

    Environment

    Temperature

    Work: -15℃ ~ 55℃ Storage: -25℃ ~ 70℃

    Humidity

    Relative humidity ≤93%

    Altitude

    ≤2500m

    Switching output

    2 way 3A 250VAC /3A 30VDC

    Switching input

    6 way dry contact

    Communication

    RS485/Modbus-RTU

    Installation

    DIN35mm guide rail or floor mounted

    Protection grade

    IP20

    Pollution levels

    2

    Security

    Insulation

    All terminals and the insulation resistance between the conductive pieces not below 100 m Ω

    Pressure

    A circuit voltage and current signal // B circuit voltage and current signal // Switching output // other ports should meet AC2kV 1min between pairs,switching input and other ports should meet AC0.5kV 1min,leakage current should be less than 2mA,no breakdown or flash over phenomenon.

    Electromagnetic    compatibility

    Anti static interference

    Class 4

    Resistance to rapid transient pulse groups

    Class 3

    Resistant to surge interference

    Class 4

    Radio frequency electromagnetic radiation

    Class 3